Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev Bras Ter Intensiva ; 34(3): 319-326, 2022.
Artigo em Português, Inglês | MEDLINE | ID: mdl-36351064

RESUMO

OBJECTIVE: To evaluate the effectiveness of the Welch Allyn Connex® Spot Monitor/Hillrom Connecta™ solution in activating the rapid response team in a timely manner compared to manual activation. METHODS: The Hillrom study is a single-center, open-label, superiority, cluster-randomized, parallel-group (1:1 allocation ratio) clinical trial that will be conducted in a tertiary hospital. Two sets of three wards with 28 beds will be included (one as the intervention cluster and the other as the control). The wards will be randomly assigned to use the Welch Allyn Connex® Spot Monitor/Hillrom Connecta™ automated solution (intervention cluster) or to maintain the usual routine (control cluster) regarding rapid response team activation. The primary outcome will be the absolute number of episodes of rapid response team triggering in an appropriate time; as secondary outcomes, clinical features (mortality, cardiac arrest, need for intensive care unit admission and duration of hospitalization) will be assessed according to clusters in an exploratory way. A sample size of 216 rapid response team activations was estimated to identify a possible difference between the groups. The protocol has been approved by the institutional Research Ethics Committee. EXPECTED RESULTS: The Welch Allyn Connex® Spot Monitor/Hillrom Connecta™ automated solution is expected to be more effective in triggering the nurse call system to activate the rapid response team in a timely and adequate manner compared to manual triggering (usual practice). CLINICALTRIALS.GOV: NCT04648579.


OBJETIVO: Avaliar a eficácia da solução Welch Allyn Connex® Spot Monitor/Hillrom Connecta™ em acionar o time de resposta rápida em tempo hábil, em comparação com o acionamento manual. MÉTODOS: O estudo Hillrom é um ensaio clínico unicêntrico, aberto, de superioridade, randomizado em clusters em paralelo (taxa de alocação 1:1) realizado em um hospital terciário. Serão incluídos dois grupos de três enfermarias com 28 leitos (um grupo intervenção e um grupo controle). As enfermarias serão distribuídas aleatoriamente para utilizar a solução automatizada Welch Allyn Connex® Spot Monitor/Hillrom Connecta™ (grupo intervenção) ou para manter a rotina habitual (grupo controle) em relação ao acionamento do time de resposta rápida. O desfecho primário será o número absoluto de ocorrências de acionamento do time de resposta rápida em tempo hábil. Como desfechos secundários, características clínicas como mortalidade, parada cardíaca, necessidade de internação em unidade de terapia intensiva e duração da hospitalização serão avaliadas de forma exploratória de acordo com os grupos. Estimou-se uma amostra de 216 acionamentos de time de resposta rápida, para identificar uma possível diferença entre os grupos. O protocolo foi aprovado pelo Comitê de Ética em Pesquisa institucional. RESULTADOS ESPERADOS: Espera-se que a solução automatizada Welch Allyn Connex® Spot Monitor/Hillrom Connecta™ seja mais eficaz no acionamento do sistema de chamada de enfermeiros, para acionar o time de resposta rápida em tempo hábil e de maneira adequada, em comparação com o acionamento manual (prática habitual). CLINICALTRIALS.GOV: NCT04648579.


Assuntos
COVID-19 , Equipe de Respostas Rápidas de Hospitais , Humanos , SARS-CoV-2 , Hospitalização , Documentação , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
Rev. bras. ter. intensiva ; 34(3): 319-326, jul.-set. 2022. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1407747

RESUMO

RESUMO Objetivo: Avaliar a eficácia da solução Welch Allyn Connex® Spot Monitor/Hillrom Connecta™ em acionar o time de resposta rápida em tempo hábil, em comparação com o acionamento manual. Métodos: O estudo Hillrom é um ensaio clínico unicêntrico, aberto, de superioridade, randomizado em clusters em paralelo (taxa de alocação 1:1) realizado em um hospital terciário. Serão incluídos dois grupos de três enfermarias com 28 leitos (um grupo intervenção e um grupo controle). As enfermarias serão distribuídas aleatoriamente para utilizar a solução automatizada Welch Allyn Connex® Spot Monitor/Hillrom Connecta™ (grupo intervenção) ou para manter a rotina habitual (grupo controle) em relação ao acionamento do time de resposta rápida. O desfecho primário será o número absoluto de ocorrências de acionamento do time de resposta rápida em tempo hábil. Como desfechos secundários, características clínicas como mortalidade, parada cardíaca, necessidade de internação em unidade de terapia intensiva e duração da hospitalização serão avaliadas de forma exploratória de acordo com os grupos. Estimou-se uma amostra de 216 acionamentos de time de resposta rápida, para identificar uma possível diferença entre os grupos. O protocolo foi aprovado pelo Comitê de Ética em Pesquisa institucional. Resultados esperados: Espera-se que a solução automatizada Welch Allyn Connex® Spot Monitor/Hillrom Connecta™ seja mais eficaz no acionamento do sistema de chamada de enfermeiros, para acionar o time de resposta rápida em tempo hábil e de maneira adequada, em comparação com o acionamento manual (prática habitual). ClinicalTrials.gov: NCT04648579


ABSTRACT Objective: To evaluate the effectiveness of the Welch Allyn Connex® Spot Monitor/Hillrom Connecta™ solution in activating the rapid response team in a timely manner compared to manual activation. Methods: The Hillrom study is a single-center, open-label, superiority, cluster-randomized, parallel-group (1:1 allocation ratio) clinical trial that will be conducted in a tertiary hospital. Two sets of three wards with 28 beds will be included (one as the intervention cluster and the other as the control). The wards will be randomly assigned to use the Welch Allyn Connex® Spot Monitor/Hillrom Connecta™ automated solution (intervention cluster) or to maintain the usual routine (control cluster) regarding rapid response team activation. The primary outcome will be the absolute number of episodes of rapid response team triggering in an appropriate time; as secondary outcomes, clinical features (mortality, cardiac arrest, need for intensive care unit admission and duration of hospitalization) will be assessed according to clusters in an exploratory way. A sample size of 216 rapid response team activations was estimated to identify a possible difference between the groups. The protocol has been approved by the institutional Research Ethics Committee. Expected results: The Welch Allyn Connex® Spot Monitor/Hillrom Connecta™ automated solution is expected to be more effective in triggering the nurse call system to activate the rapid response team in a timely and adequate manner compared to manual triggering (usual practice). ClinicalTrials.gov: NCT04648579

3.
J Breath Res ; 10(4): 046018, 2016 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-28000620

RESUMO

In this study, the effects of aerobic exercise on the upper airways and their defense mechanisms were investigated in athletes. The athletes ran in two different environments: the downtown streets of the city of São Paulo (Street), more polluted, and an urban forest (Forest), less polluted. Thirty-eight young healthy athletes ran for 45 min d-1 randomly during five consecutive days, with an interval of 48 h before changing environment. Clinical parameters and respiratory tract defense markers were evaluated before and after the first run on Mondays (1 d) and on Fridays (5 d). Street presented higher mean PM2.5 concentrations (65.1 ± 39.1 µg m-3, p < 0.001) and lower temperature (22.0 °C, p = 0.010) than Forest (22.6 ± 15.3 µg m-3 and 22.8 °C). After 1 d Street running, subjects showed an increment in heart rate (p < 0.001). At day 5, there was twice the number of athletes with impaired nasal mucociliary clearance (MCC) in the Street runners group when compared to the Forest runners group. Exhaled breath condensate pH values increased in the Forest group, with significant differences between groups in day 1 (p = 0.006) and day 5 (p < 0.001), despite the fact that both groups showed values within the normal range. After exposure to both environments, the number of cells in the nasal lavage fluid was reduced after exercise (p = 0.014), without alterations in cell type and IL-8 and IL-10 concentrations. Aerobic exercise can either maintain or acutely enhance MCC and it may help to regulate inflammatory responses in the airways. Here we show that exercise practice in polluted outdoor environment, over a 5 d period, impairs MCC. In contrast, athletes running in the less polluted environment (Forest) show higher exhaled breath condensate pH values when compared to those who exercised in a more polluted environment (Street).


Assuntos
Poluição do Ar/análise , Cidades , Exercício Físico/fisiologia , Pulmão/imunologia , Corrida/fisiologia , Adolescente , Adulto , Poluentes Atmosféricos/análise , Biomarcadores/análise , Testes Respiratórios , Demografia , Expiração , Florestas , Humanos , Umidade , Concentração de Íons de Hidrogênio , Masculino , Material Particulado/análise , Temperatura , Adulto Jovem
4.
Chest ; 145(5): 998-1005, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24307008

RESUMO

BACKGROUND: Smoking is responsible for most COPD. Although people with COPD often have concomitant nasal disease, there are few studies that report physiologic or inflammatory changes in the upper airways in young asymptomatic smokers. We investigated physiologic and inflammatory changes in the nasal and lower airways of young smokers and if these changes were related to smoking history. METHODS: Seventy-two subjects aged between 18 and 35 years (32 healthy nonsmokers and 40 young smokers) participated in this study. We measured nasal mucociliary clearance (MCC), nasal mucus surface contact angle, cell counts, myeloperoxidase and cytokine concentrations in nasal lavage fluid, exhaled breath condensate (EBC) pH, and lung function. RESULTS: Smokers had faster MCC, an increased number of cells (macrophages, ciliated cells, and goblet cells), increased lavage myeloperoxidase concentration, and decreased EBC pH compared with nonsmokers. There was a significant inverse relationship between pack-year smoking history and EBC pH. There were no differences in lung function or mucus surface properties comparing smokers to nonsmokers. CONCLUSIONS: Young adult smokers have functional and inflammatory changes in the nasal and lower airways and these correlate with smoking history. However, in these young smokers, smoking history was not associated with pulmonary function decline, probably because it is unlikely that spirometry detects early physiologic changes in the airways. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT01877291; URL: www.clinicaltrials.gov.


Assuntos
Expiração , Inflamação/metabolismo , Depuração Mucociliar/fisiologia , Mucosa Nasal/metabolismo , Peroxidase/metabolismo , Mucosa Respiratória/metabolismo , Fumar/metabolismo , Adolescente , Adulto , Ar/análise , Testes Respiratórios , Contagem de Células , Feminino , Humanos , Concentração de Íons de Hidrogênio , Masculino , Líquido da Lavagem Nasal/química , Líquido da Lavagem Nasal/citologia , Fumar/efeitos adversos , Fumar/fisiopatologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...